Split-core Current Sensor
2.Delicate appearance.
3.Customized type available.
4.Lower price.
Opis
Tehničke karakteristike
Split-Core Current Sensor - IEC 61869 Class 0.5, Non-Invasive Retrofit CT for Energy Monitoring & SCADA
Reviewed by [Engineer Name], Senior Magnetic Components Engineer - [X] years in split-core CT design & field application, Fullstar Electronics
This page is structured as a selection and risk-reduction resource. Jump to: Technical Specifications|Standards & Compliance|Application Solutions|Downloads|Selection & Installation Notes|FAQ

1. What this sensor is - and what it is not
A split-core current sensor (also called split-core CT) opens around an existing primary conductor without disconnecting the cable or interrupting the load. It is the standard choice for retrofit energy monitoring, sub-metering, and load studies where shutdown is not acceptable.
It is not a solid-core CT replacement for every case. The split-core air gap introduces a small magnetic penalty compared with a closed-core design at the same nominal rating. Fullstar's SCT series is engineered to keep that penalty within IEC 61869 Class 0.5 / Class 1.0 limits across the rated range, verified on our in-house calibration bench for every production batch. If your application requires 0.2S revenue-grade accuracy at very low current, a solid-core or Rogowski solution may be more appropriate - contact our engineer before selecting.
2. Technical Specifications
| Split-core AC current transformer / sensor | |
| IEC 61869-20.5 / 1.0 | |
| 0.01 A – 10,000 A (model-dependent) | |
| 33.3 mA, 100 mA, 1 A, 5 A; voltage output (e.g., 0.333 V) available on request | |
| 0.5 / 1.0 (IEC 61869-2) - model-specific | |
| 10 mm / 16 mm / 24 mm / 36 mm (custom sizes available) | |
| 50–60 Hz standard; 50 Hz–1 kHz on select models | |
| Epoxy resin encapsulated; ABS / PBT flame-retardant housing (UL94-V0 where applicable) | |
| [-] ℃ to [-] ℃ | |
Model-specific datasheets with ratio error and phase displacement curves are available in the Download Center. Do not select by nominal current alone - phase error at your operating current is often the real limiting factor in energy-metering accuracy.
3. Standards & Compliance - what you can verify
| IEC 61869-2 | Type test / routine test per Class 0.5 or 1.0 (model-specific) | |
| ISO 9001:2015 | Certificate No. [-], issued by [-], valid until [-] | |
| [If applicable: UL 61010 / UL 2808 recognized component - file number [-]] | ||
| In-house accuracy calibration bench, insulation resistance tester, and epoxy cure monitoring records |
If a certificate is not currently held for a specific model, we state that honestly. A lapsed or inapplicable certification displayed without scope is worse than a clear "available upon request" - procurement teams verify.
4. Application Solutions - matched to the way you actually buy
4.1 Retrofit energy monitoring without cable disconnection
Building or data-center feeders cannot be shut down for CT installation.
SCT split-core series with locking snap closure - installs around existing cable in minutes, no torque tool required.
SCT016T / SCT024TS for 120–400 A feeders; SCT036TS for 600 A feeders.
Installation time comparison data (customer trial): [X] min per CT vs. [Y] min for solid-core replacement. Full application note: - Download.
4.2 Revenue-grade sub-metering for energy-meter OEMs
Meter OEM needs stable ratio and phase error across 2–120% of rated current to maintain billing accuracy.
Epoxy-encapsulated split-core CTs with batch-level calibration data; Class 0.5 compliant units with test report per batch.
SCT010T / SCT016TS for 80–150 A; custom ratios available.
[If applicable: "Batch calibration data shows phase error < [X]℃ at 5% rated current" - request sample calibration sheet.]
4.3 Load studies and temporary monitoring in SCADA / power-quality systems
Field engineers need a safe, low-voltage output that interfaces with data loggers and RTUs.
Voltage-output (0.333 V) split-core sensors with standardized connector options; compact window sizes for crowded panels.
[Model] with voltage output; [Model] with 1 A secondary.
Wiring diagram and output burden compatibility table in datasheet.
Split-core CTs are not interchangeable across all power-quality meters. Check the meter's burden and the CT's secondary output type before ordering. If you send us your meter model and feeder current, our engineer will confirm compatibility in writing - Request compatibility check.
5. Downloads - engineering resources for your evaluation
| Closure inspection, air-gap cleanliness, conductor centering, lead routing, torque-free locking check | ||
| 2D Drawing / 3D STEP | ||
| IEC 61869-2 / RoHS / REACH statements | ||
| ISO 9001 Certificate | ||
| Step-by-step retrofit workflow with photos and common installation errors |
Send your window size, rated current, output requirement, and target accuracy class - we will return a selection table and sample lead time within [X] business hours.
6. Selection & Installation Notes - from our engineering team
Engineer's Note 1 - Air gap is the accuracy killer in split-core CTs.
The mating surfaces of the core halves must be clean and fully closed before the lock engages. A single layer of paint, dust, or oxidation at the gap can shift phase error enough to fail a Class 0.5 check at low current. We recommend wiping the mating faces with a dry lint-free cloth immediately before closing, and never forcing the lock if resistance is felt.
Engineer's Note 2 - Centering matters more than most datasheets admit.
An off-center primary conductor in the window introduces an additional error component. For Class 0.5 work, keep the conductor centered within [X] mm of the window center. If the cable bundle is irregular, use a cable tie to bundle and center it before closing the CT.
Engineer's Note 3 - Do not rely on nominal current alone for model selection.
A 400 A CT used on a feeder that idles at 20 A may still have acceptable ratio error, but phase error at that low current can dominate the meter's accuracy budget. If your load profile includes long low-current periods, ask for phase-error data at 1–5% rated current, not just at nominal. We provide this data on request for all Class 0.5 models.
We a premier professional manufacturer specializing in magnetic components and electronic solutions. Founded in 2009 and headquartered in the high-tech hub of Xi'an, we have accumulated over 15 years of deep expertise in the research, development, and production of high-performance transformers and inductors. Our facility spans 3,000 square meters and is powered by a dedicated workforce of 300+ skilled professionals, including a senior R&D team focused on bespoke magnetic designs.
Our comprehensive product line features high-frequency and low-frequency transformers, toroidal transformers, current transformers, and a wide variety of inductors and magnetic cores. As a Top 6 leading factory for Industrial Controls, we provide critical components for power supplies, telecommunications, automotive electronics, and green energy sectors globally.
Quality is our core competency. Fullstar operates under a strict ISO9001:2015 Quality Management System. Our products carry international safety and environmental certifications including UL, CE, RoHS, and REACH. Every unit undergoes a 100% rigorous testing process before shipment to ensure zero-defect reliability in demanding industrial environments.
We excel in customization. With advanced design-based and sample-based capabilities, we offer rapid 7-day prototyping and flexible OEM/ODM services. Our supply chain reaches over 80 countries, providing localized support and cost-effective logistics. Whether you require high-volume production or small-batch custom coils, Fullstar delivers precision-engineered magnetic components that drive your innovation forward. We welcome global business inquiries for long-term strategic partnerships.



Q: What is the difference between your split-core sensor and a solid-core CT?
A: Split-core installs without disconnecting the conductor; solid-core typically requires shutdown or cable re-routing. Split-core has a small magnetic penalty from the air gap. For retrofit and temporary monitoring, split-core is usually the pragmatic choice; for permanent revenue metering at very low current, evaluate solid-core or Rogowski alternatives with our engineer.
A: Yes. Standard sample lead time is [X] business days. Samples can be supplied with a calibration record for the requested accuracy class. MOQ for custom ratios/leads applies after sample approval.
A: ISO 9001 certificate, IEC 61869-2 test report (model-specific, under NDA where required), RoHS/REACH DoC, and dimensional/CAD files. See the
Download Center.
Q: What is the warranty and failure-handling policy?
A: [X]-month warranty against manufacturing defects. For batch-level issues, we provide replacement or credit after root-cause analysis; field failure samples should be returned for teardown and 8D report.
A: Yes, for OEM volumes. Customization requires a drawing approval and [X]-week tooling/lead time. Send your specification for feasibility review.
Popularne oznake: split-core current sensor, China, manufacturer, supplier, factory, wholesale, price, for sale, electronic components, passive components, customer-made, standard
Pošalji upit


















